Translucent Liquid Colorimetry: Transmission Measurement & Industry Scales

Replace subjective visual judgment with objective spectrocolorimetric qualification. From instant calculation of CIE Lab coordinates and ΔE color differences in a standard cuvette to in-line control with an immersion probe, make the compliance of your baths, oils, beverages and solvents reliable.

Why move away from visual comparison with color charts?

In the food, chemical, cosmetics and petroleum industries, the color of a translucent liquid is the first indicator of purity, aging, thermal degradation or formulation compliance. Yet traditional visual inspection has major limitations:

  • Eye variability and fatigue: the assessment of subtle hues (pale yellows, ambers, pinkish tints) varies with ambient lighting and each operator’s own sensitivity.
  • Perishable physical standards: liquid reference standards and comparator discs fade over time under the effect of light and oxidation.
  • No digital traceability: visual checks cannot be integrated into statistical process control or a quality certification approach.
The GoyaLab spectrophotometric solution:
Spectral analysis in transmission captures the full transmittance spectrum T(\lambda) between 380 and 720 nm (or extended up to 900 nm). SpectroLab software applies the standard observer (CIE 2° or 10°) and illuminant (D65, A, C) functions to derive tamper-proof mathematical coordinates and standardized industry indices.

IndiGo Color in transmission: the portable reference for standard cuvettes

Industry color scales available in SpectroLab

In addition to the universal CIE Lab spaces, SpectroLab includes, at the customer’s request, direct calculation algorithms for the standardized scales of each industry:

Pt-Co / Hazen / APHA scale

ISO 6271 / ASTM D1209 standard to qualify the residual yellow color of clear liquids, high-purity solvents, resins, plasticizers, acids and clear water (range 0 to 500 Pt-Co).

Gardner index

ISO 4630 / ASTM D1544 standard for darker, amber liquids: drying oils, industrial varnishes, fatty acids, resins and molten polymers (scale from 1 to 18).

Saybolt & ASTM D1500 scales

Specific to refined petroleum products: the Saybolt scale (ASTM D156) for aviation fuels and clear kerosenes, and ASTM D1500 for base oils, lubricants and hydraulic fluids.

Brewing & winemaking (EBC / SRM / OD420)

Direct calculation of beer color according to the EBC (European Brewery Convention) and SRM standards, plus monitoring of hue, color intensity and yellowing of white and rosé wines.

Advanced configurations: in-situ measurement & micrometric positioning

Fiber-coupled IndiGo VIS-NIR: in-situ immersion probe

To check the color of a liquid directly in a reactor, a formulation beaker or a brewing tank, with no manual sampling into a cuvette:

  • Reflection-type transmission probe: fixed path length (2, 5 or 10 mm) in stainless steel or titanium with sapphire windows.
  • SMA 905 optical connection: the spectrometer stays away from the chemical immersion area.
  • Continuous spectral monitoring: real-time tracking of hue changes during mixing or clarification.

The 3D Stand: repeatability on specific containers

For liquids packaged in test tubes, sealed ampoules or specific vials that do not fit a standard cuvette holder:

  • Micrometric 3-axis adjustment: alignment of the incident beam with the exact optical center of the tube or vial.
  • Stable, vibration-free holding: prevents any change in path length during comparative series measurements.
  • Ideal for laboratory control: turns the IndiGo into a fixed colorimetric metrology station.

Target industries

Food, beverages & oils

Compliance testing of vegetable oils (olive, sunflower, rapeseed), liquid honeys, syrups, vinegars, beers (EBC) and spirits. Early detection of oxidation or thermal degradation.

Fine chemicals, polymers & resins

Purity validation of industrial solvents, monomers, adhesives and synthetic resins with the Hazen/APHA or Gardner scale, to rule out unwanted yellowing.

Cosmetics & perfumery

Consistent color of translucent lotions, eaux de toilette, fragrance bases and serums from one production batch to the next, despite variations in natural ingredients.

Petrochemicals & lubricants

Characterization of mineral oils, coolants, fuels and hydrocarbon solvents according to the Saybolt and ASTM D1500 standards, to certify the level of refining.

Software engineering & OEM

Need a dedicated pass / fail app or a custom Python script?

Do you apply a proprietary color formula or a specific tolerance ellipse, or want to give your plant operators an instant green / red verdict? GoyaLab develops your dedicated smartphone apps (Android / iOS), standalone Windows software or custom Python scripts interfaced directly with your PLCs and quality databases.

Talk to our engineering team

GoyaLab configurations for liquid colorimetry

GoyaLab solution Optical principle Scales & data Typical industrial applications
IndiGo Color in transmission Visible spectrophotometry in a cuvette (10 mm) CIE L*a*b*, XYZ, ΔE*, APHA, Gardner Laboratory and production quality control: vegetable oils, pure solvents, resins, beverages, perfumes and cosmetics.
IndiGo fiber + immersion probe In-situ transmission, no cuvette (SMA 905) 380 – 900 nm, L*a*b*, custom indices Direct measurements in reactors, formulation beakers and brewing tanks, with no sample handling in cuvettes.
IndiGo + 3D Stand Micrometric 3-axis positioning Transmission on special containers Color control of liquids in test tubes, sealed ampoules or vials with specific shapes.
Dedicated pass / fail & Python apps Custom software development (OEM) ΔE* tolerances & proprietary indices Ultra-simple operator interface for the shop floor, binary green/red qualification and direct LIMS integration.