IndiGo fluo laser-532: a fluorescence spectrometer with a 532nm laser excitation

The IndiGo Fluo Laser 532 nm is a portable, standalone spectrofluorometer engineered for high-sensitivity detection and quantitative analysis of fluorophores, biomolecules, and advanced materials under coherent green excitation. Driven by a 100 mW single-mode 532 nm laser source delivering stabilized continuous-wave (CW) emission, it provides photon flux density and spectral purity far exceeding standard LED illumination, enabling trace-level detection down to the sub-ppm range.

Featuring a dual-stage high-rejection optical filtering architecture (laser clean-up filter and a 540 nm long-pass collection edge), an uninhibited detection range spanning 532 to 840 nm, interchangeable MPLAN microscope objectives, and Class 1 interlocked sampling enclosures, the IndiGo Fluo Laser 532 nm brings laboratory-grade precision directly into mobile, QA/QC, and field workflows.


Optical Architecture & 532 nm Laser Excitation Key Features

  • Single-mode 532 nm laser excitation (100 mW): frequency-stabilized, single-mode CW laser diode delivering a narrow, coherent excitation beam. Laser power is fully adjustable step-by-step via SpectroLab software to optimize signal yield while preventing photobleaching.
  • Dual-stage high-rejection spectral filtering:
    • 532 nm clean-up laser filter: positioned at the laser output to strip amplified spontaneous emission (ASE) and guarantee an ultra-pure excitation line.
    • Long-Pass (LP) 540 nm collection filter: sharp optical edge filter at the spectrometer slit entrance, blocking laser backscatter to acquire fluorescence emission right from the immediate vicinity of the excitation line.
  • Useful spectral range (532 – 840 nm): continuous coverage optimized across the yellow, orange, red, and very near-infrared emission bands.
  • Interchangeable MPLAN focusing objectives: fitted as standard with a high-grade metallurgical MPLAN 10x objective, swappable tool-free to a 4x (wide-field macroscopic collection) or a 60x (micrometric spot size for high power density).
  • Configurable entrance slits & optical resolution:
    • 25 µm slit: maximum optical resolution < 1.5 nm (resolving narrow emission lines and fine multiplets).
    • 70 µm slit (Standard): resolution < 5.0 nm (balanced sensitivity and throughput for routine workflows).
    • 150 µm slit: resolution < 10 nm (maximum photon throughput for ultra-low quantum yield samples).
  • Scientific CMOS detector options:
    • Sony IMX334 monochrome: 2D high-resolution CMOS sensor with ultra-low readout noise and high dynamic range for demanding quantitative fluorimetry.
    • ON Semi MT9M001: field-proven and cost-effective configuration for routine quality control and higher education.
  • Certified operational laser safety:
    • Class 1 (total safety): eye-safe operation without protective eyewear when utilizing fully enclosed sample compartments with physical contact interlocks.
    • Class 3B: open sampling setups or direct optical bench integration.

Modular Sampling: From Vials to Bulk Solids

The IndiGo Fluo Laser 532 nm interfaces seamlessly with the comprehensive suite of IndiGo modular holders:

  • Cylindrical vial holders: secure adapter for standard Ø 10 mm borosilicate glass vials and sampling tubes.
  • Spectroscopy cuvette holders: accommodates standard 10 × 10 mm optical cuvettes (quartz, optical glass, or polystyrene).
  • Powder, pellet & solid sample holders: dedicated cup adapter for surface evaluation of packed powders, compressed tablets, and bulk specimens.
  • Custom adaptations: in-house engineering and rapid prototyping of bespoke sample fixtures tailored to your production or testing formats.

Key Applications & Analytical Fields

Laser excitation at 532 nm aligns with the absorption peaks of widely used fluorophores, biomolecules, and inorganic luminescent centers:

  • Biotechnology, molecular biology & diagnostics:
    • Reference fluorophores: resonant excitation of Rhodamine dyes (Rhodamine B, Rhodamine 6G), Cyanine 3 (Cy3), Alexa Fluor 532 / 546, and propidium iodide.
    • Phycobiliproteins & biomarkers: sensitive quantification of B-phycoerythrin (B-PE) and R-phycoerythrin (R-PE) used in immunoassay diagnostics.
  • Nanomaterials & quantum photonics:
    • Fluorescent nanodiamonds & NV centers: optical characterization of nitrogen-vacancy centers (NV0 at 575 nm and NV– at 637 nm) for nanoscale thermometry, quantum sensing, and bio-tagging.
    • Quantum dots & phosphors: emission efficiency and stability monitoring for nanocrystals emitting in the yellow, orange, and deep red regions.
  • Agri-food, edible oils & beverages:
    • Lipid oxidation & thermal stress: screening oil degradation and adulteration via laser-induced fluorescence of secondary oxidation products.
    • Beverage fingerprinting: spectral profiling of phenolic compounds and aging markers in premium spirits and wines.
  • Mineralogy, geology & gemology:
    • Luminescent activators & rare earths: resolving characteristic emission signatures from chromium (Cr3+), samarium (Sm3+), and europium (Eu3+) in spinels, rubies, and activated calcites.

Technical Specifications

Parameter Specification
Excitation laser source 532 nm single-mode laser (Single Mode), continuous wave (CW)
Optical output power 100 mW (dynamically adjustable via SpectroLab software)
Integrated optical filters 532 nm clean-up filter + Long-Pass (LP) 540 nm collection filter
Spectral detection range 532 – 840 nm
Focusing objective MPLAN 10x mounted standard (swappable to 4x or 60x)
Entrance slit & resolution (FWHM) 25 µm (< 1.5 nm) | 70 µm standard (< 5 nm) | 150 µm (< 10 nm)
Detector options Sony 2D CMOS IMX334 monochrome (high sensitivity) or MT9M001
Sampling modules (Holders) Vials (Ø 10 mm), cuvettes (10 × 10 mm), and solid/powder presentation cups
Laser safety classification Class 1 with interlocked closed holder / Class 3B in open-beam operation
Power supply & connectivity Internal rechargeable Li-ion battery, wireless Bluetooth BLE, and USB-C port

SpectroLab Software Ecosystem & Chemometrics

  • SpectroLab (Included, free, unlimited license): real-time laser power control, live spectral display from 532 to 840 nm, dark subtraction, peak area integration, and standard data export formats (.xlsx, .csv, .txt, .spc).
  • Expert / Capture chemometrics suite (Option): multivariate statistical classification (PCA) for origin tracing or sample sorting, and PLS regression models for precise fluorophore quantification in complex mixtures.

💡 Evaluate 532 nm Laser Fluorescence on Your Samples

Looking to detect a specific fluorophore (Rhodamines, PE), characterize nanodiamonds, or design a custom sampling fixture for your line?

👉 Contact our application engineering team for a demonstration or feasibility study


Interested in this product ? Request a quote

    By submitting this form, I accept the personal data management policy

    Our GoSpectro and GemSpectr apps are available on the stores:

    Available on App Store Available on Google Play

    Application

    The applications are unlimited. Today our expertise is focused in particular on the following areas

    Extra Virgin Olive Oil absorption

    Chemical analysis

    experiments-education-research-GoyaLab

    Education – Research

    Handheld-spectrometer-gemmology-gems-jewels-jewellery-GoyaLab

    Gemology and Jewellery

    Lightng-filters-identification-GoyaLab

    Lighting and filters identification

    counterfeit-authentication-products-quality-hand-spectrometer-GoyaLab

    Traceability and authentication

    Applications-fields-action-GoyaLab

    Others